HAEGER Air Glass AF-G45-006A Instrucciones De Uso página 12

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 26
Troubleshooting
Problem
Smoke and smell when using the
machine for the first time.
The machine does not work.
The machine does not heat.
Glass pot is broken.
Error Code
E1
E2
E3
Technical Data
Product Model
Rated Power
Rated Voltage
Capacity
Timer range
Temperature range
Reason
NTC is broken
NTC make short-circuit
Heating tube is broken
Power board is broken
The connection wire between the
heating tube and the power board is
loose
Solution
When using for the first time, bake for 5
minutes without food, so as to completely
evaporate the protective grease of the parts.
Check whether the plug is properly inserted
into the socket and whether the glass pot is
placed correctly.
Check whether the switch is activated and
whether the carbon fibre heating tube is
illuminated.
If the heating tube does not light up, please
contact the after-sales service.
Please contact the after-sales service.
AF-G45.006A
1200W
220-240V~, 50Hz
4.5L
1-60 minutes
60°C - 200°C
English - 9
Solution
Replace NTC
Replace NTC
Replace heating tube
Replace the power board
Check the connection wire.
loading