Parameter
Size
Number
32
4
Parameters Values
Value
Description
0-360000 Specific time expressed in tenth of seconds for Status change.
Association group management
This section defines the configuration parameters associated respectively with the
control groups G1, G2, and dimming.
Parameter
Size
Number
40
1
Parameters Values
Value
Description
0
No control
1
1 click
2
2 clicks
4
3 clicks
8
Hold down
16
Up
If you support more than 1 event, the value for the configuration parameter is the sum
of the event values.
For example:
1 click and 2 clicks -> Parameter value must be 1 + 2 = 3
1 click and 3 clicks -> Parameter value must be 1 + 4 = 5
Default value: 1 click →1
Parameter
Default
Name
Value
ON_
0
TIMEOUT
Parameter
Default
Name
Value
G1_SETUP
1
Description
Time in tenth of seconds after which the
output will be switched On.
Min: 0
Description
Define which events on the input control
G1 association group.
Min: 0
43
Max: 360000
Max: 31