TIMER MANAGEMENT
A timer can be set when switching On and/or Off. It is also possible to define which
event will start the timer. (for example only the change on the output due to double
clicks).
RESET TO THE FACTORY SETTINGS
The device can be reset to the original factory with 6 consecutive clicks on the
integrated button.
After the reset is completed, the device will reboot and a RED solid led is showed.
Please use this procedure only when the network primary controller is missing or
otherwise inoperable.
INFO: If the reset is performed while the device is still part of a network, it
notifies the other devices that it has been removed (Device Reset Locally
Notification).
FIRMWARE UPDATE
The system supports over-the-air firmware updates that do not require the device to
be removed from its location. The firmware update can be activated from all certified
controllers supporting version 2 of the Firmware Update function.
WARNING: The system will be rebooted at the end of the firmware update
procedure. It is advisable to carry out the firmware update procedure only when
necessary and following careful planning of the intervention.
37