Hitachi Koki C 18DL Manual De Instrucciones página 13

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Before
Charge
charging
status
lamp (RED)
While
charging
Charging
complete
Charging
impossible
Overheat
Overheat
lamp
standby
(GREEN)
NOTE: When standby for cooling battery, UC18YRL cools the overheated battery by cooling fan.
Regarding the temperature of the rechargeable
battery.
The temperatures for rechargeable batteries are
as shown in the Table 3, and batteries that have
become hot should be cooled for a while before
being recharged.
Table 3
Rechargeable
Temperatures at which the
batteries
battery can be recharged
EBM1830, BCL1815 32°F — 122°F (0°C — 50°C)
4.
Disconnect battery charger from the receptacle.
CAUTION:
Do not pull the plug out of the receptacle by pulling
on the cord.
Make sure to grasp the plug when removing from
receptacle to avoid damaging cord.
5.
Remove the battery from the battery charger.
Supporting the battery charger with hand, pull out
the battery from the battery charger.
<UC18YGL2>
1.
Insert the plug of battery charger into the
receptacle.
When the plug of battery charger has been inserted
into the receptacle, pilot lamp will blink in red. (At
1-second intervals)
Table 2
Indications of the pilot lamp
Blinks
Lights for 0.5 seconds. Does not light
(RED)
for 0.5 seconds. (off for 0.5 seconds)
Lights
Lights continuously
(RED)
Lights for 0.5 seconds. Does not light
Blinks
for 0.5 seconds. (off for 0.5 seconds)
(RED)
Lights for 0.1 seconds. Does not light
Flickers
for 0.1 seconds. (off for 0.1 seconds)
(RED)
Lights
Lights continuously
(GREEN)
WARNING
Do not use the electrical cord if
damaged. Have it repaired
immediately.
2.
Insert the battery to the battery charger.
Insert the battery into the battery charger as shown
in Fig. 6. Make sure it contacts the bottom of the
battery charger.
3.
Charging
When the battery is connected to the battery
charger, charging will commence and the pilot
lamp will light in red. (See Table 4)
English
Malfunction in the
battery or the charger
Battery overheated.
Unable to charge
(Charging will commence
when battery cools).
Pilot lamp
Fig. 6
13
Tabla de contenido
loading

Tabla de contenido