www.nortonabrasives.com
Code
Description
78072756714 Flat filter Class M
78072756713 Flexible hose D.33mm x 4m AS
78072756704 Flexible hose D.29mm x 4m AS
PROBLEM
The suction motor does not
start and does not work.
(For Class M and H versions)
The filter "
" and suction
"
" LEDs are off.
Suction is poor.
(For Class M and H versions)
The suction LED "
es and the acoustic warning
is sounded; Air speed in the
tube ≤ 20 m/s.
(For Class H version) The
suction is poor, the filter
LED "
" is flashing and the
acoustic warning is sounded.
SPARE PARTS
TROUBLESHOOTING
CAUSE
Plug not inserted.
No current.
Suction motor overheated.
Suction motor damaged.
Suction tube diameter switch
not combined with the flexible
" flash-
tube used.
Waste container full.
Fleece bag full.
Filter elements clogged.
Accessories
clogged.
Damaged vacuum motor.
Suction
nozzle
worn or damaged.
No cartridge filter.
Cartridge filter clogged or
damaged.
ENGLISH - 9
M Class
Insert the plug into the electri-
cal socket.
Check the power supply line.
Check that the motor is work-
ing correctly.
Replace the motor. (*)
Turn the switch to the correct
diameter of the flexible tube
used.
Empty container.
Replace the dust bag.
Clean the filter components.
Clean or replace the cartridge
filter.
or
tubes
Check and clean the flexible
tube and the suction nozzle.
Replace the motor. (*)
squeegee
Check and replace the
squeegee.
Install the filter.
Clean or replace the filter.
*Norton Class H model not available
L Class
■
■
■
■
■
■
SOLUTION