enphase HCS-40 Manual De Instalación Y Funcionamiento página 29

Ocultar thumbs Ver también para HCS-40:
Idiomas disponibles

Idiomas disponibles

HCS Installation and Operation Manual
Specifications
Line input power
Voltage and wiring
Supplied input
Frequency
CCID
Current and output power
(at 240 VAC)
Note: The maximum current for the vehicle is set by the duty cycle of the Pilot waveform. Output power is variable
depending upon the HCS model and vehicle demand.
Plugs
Dimensions
Weight
Environment
Enclosure rating
Agency approvals
January 2024
140-00277-03
208 VAC 3-phase wye-connected - Any two phases and Safety Ground. 240 VAC 3-phase, delta-connected.
With center-tap on one leg, you must use only the two phases on either side of the center-tap.
The two phases must both measure 120 VAC to ground. Do not use the third leg (208V "Stinger").
Pre-installed supplied input conductors of the
supplied input conductors of the HCS-50R, HCS-60R, and HCS-80R: L1, L2, and Ground use 3 ft of 8 AWG, 90ºC copper wire.
HCS Model
Number
HCS-40R (hardwired)
HCS-40PR + (6-50 plug)
HCS-40PR + (14-50 plug)
HCS-50R (hardwired)
HCS-50PR + (6-50 plug)
HCS-50PR + (14-50 plug)
HCS-60R (hardwired)
HCS-80R (hardwired)
An attached NEMA 6-50P or NEMA 14-50P plug is available on plug-type EVSE units.
A suitable receptacle is also supplied - please review the manual for proper installation guidelines.
HCS-40R or HCS-40PR with 40A SAE J1772 connector and 25' length of cable: 6.1kg (13.5 lbs)
HCS-50R or HCS-50PR with 40A SAE J1772 connector and 25' length of cable: 6.3kg (14 lbs)
HCS-60R with 48A SAE J1772 connector and 25' length of cable: 9.0 kg (21 lbs)
HCS-80R with 64A SAE J1772 connector and 25' length of cable: 9.0 kg (21 lbs)
ETL Listed, FCC Part 15 Class B, ENERGY STAR
© 2024 Enphase Energy Inc. All rights reserved.
240 VAC single-phase - L1, L2, and Safety Ground.
HCS-40R: L1, L2 and Ground use 3 ft of 10 AWG, 90ºC copper wire. Pre-installed
50/60 Hz
20 mA
Circuit
Max
Breaker
Current
40 A
32 A
40 A/50 A
32 A
40 A/50 A
32 A
50 A
40 A
50 A
40 A
50 A
40 A
60 A
48 A
80 A
64 A
Dimensions are for the enclosure only:
Height: 19.7 inches (500 mm)
Width: 8.9 inches (226 mm)
Depth: 5.3 inches (135 mm)
Operating temperature: -22°F to 122°F (-30°C to 50°C)
Storage temperature: -40°F to 176°F (-40°C to 80°C)
NEMA 4 - watertight
®
Certified NOM (for particular models)
Output
Cable
Power
Length
7.7 kW
25 ft (7.6 m)
7.7 kW
25 ft (7.6 m)
7.7 kW
25 ft (7.6 m)
9.6 kW
25 ft (7.6 m)
9.6 kW
25 ft (7.6 m)
9.6 kW
25 ft (7.6 m)
11.5 kW
25 ft (7.6 m)
15.4
kW
25 ft (7.6 m)
29