EVSE mounting for hollow-wall construction
Place the unit such that both mounting holes can take advantage of solid structural framing inside of the wall or
a strong wall surface such as plywood.
Size ¼" - 20 lag screws are recommended for mounting the EVSE to a wooden structure. Pre-drill appropriately
sized pilot holes to allow the lag screw to grip the wooden structure while preventing the wood from cracking or
splintering while the screw is fastened.
The included plastic angle washers can be oriented to allow the lag screws to be fastened at an angle while still
providing a solid flat backing to the screw head.
If the screw head is smaller than the ⅜" (1 cm) washer aperture, an additional flat washer will need to be placed
between the plastic angle washer and the head of the lag screw.
If either mounting hole does not have a solid mounting structure (such as drywall without a solid backing). It will
be necessary to use proper anchoring hardware, such as drywall toggles or molly bolts.
Figure 9: Mounting the EVSE to a hollow wall
22
17"
© 2024 Enphase Energy Inc. All rights reserved.
HCS Installation and Operation Manual
January 2024
1140-00277-03