5. To unlock the load-bearing cable, press either the Up button or the Down button, as appropriate.
▶ The LED status indicator shows steady green.
▶ The load-bearing cable is unlocked.
If increased resistance is encountered when the attached power tool is moved up or down, the
weight of the attached power tool has to be re-initialized. To do this, briefly move the attached
power tool either up by pressing the Up button or down by pressing the Down button and then
allow the power tool to dangle freely for 2 seconds. The weight is re-initialized and the resistance
to movement is reduced again.
6.5
Detaching power tool
CAUTION
Risk of injury by unexpected movement of the load-bearing cable. Injury and/or damage caused by
upward movement or sudden drop of the attached power tool.
▶ Always lock the load-bearing cable before you detach the attached power tool.
1. Lower the attached power tool until it rests on the ground or some other firm surface.
You can also remove the power tool while it is suspended in mid-air.
2. Simultaneously press the Up and Down buttons and hold them down to block movement of the load-
bearing cable.
▶ The LED status indicator flashes green.
▶ The load-bearing cable is locked.
3. Disengage the attached power tool from the hook.
6.6
Removing
1. Press the Up button to reel in the full length of the load-bearing cable.
2. Switch the product off.
3. Tilt the ladder-lock buckles of the shoulder straps up to loosen the straps.
4. Open the clip catch of the chest strap.
5. Open the clip catch of the waist belt.
6. Shrug the product off your shoulders as if it were a backpack.
7
Care and maintenance
WARNING
Risk of injury with battery inserted !
▶ Always remove the battery before carrying out care and maintenance tasks!
Care of the product
Carefully remove stubborn dirt.
Carefully clean the air vents, if present, with a dry, soft brush.
Use only a slightly damp cloth to clean the housing. Do not use cleaning agents containing silicone as
these can attack the plastic parts.
Use a dry, clean cloth to clean the contacts of the product.
Care of the Li­ion batteries
Never use a battery with clogged air vents. Clean the air vents carefully using a dry, soft brush.
Avoid unnecessary exposure of the battery to dust and dirt. Never expose the battery to high levels of
moisture (e.g. by being dipped in water or left in the rain).
If a battery has been soaked by moisture, treat it as a damaged battery. Isolate it in a non-flammable
container and consult Hilti Service.
Keep the battery free of extraneous oil and grease. Do not permit dust or dirt to accumulate unnecessarily
on the battery. Clean the battery with a dry, soft brush or a clean, dry cloth. Do not use cleaning agents
containing silicone as these can attack the plastic parts.
Do not touch the contacts of the battery and do not remove the factory-applied grease from the contacts.
*2375781*