GE ZDP366NP2SS Instrucciones De Instalación página 21

Idiomas disponibles

Idiomas disponibles

J Ilnstallat.ion
nstructlons
I
Convert Natural Gas to LP Gas Operation
Convert LP Gas to Natural Gas Operation
-AWARNING:This conversion
must
be performed by a qualified installer or gas supplier
in accordance with the manufacturer's instructions
and all codes and requirements of the authority having
jurisdiction. Failure to follow instructions could result
in serious injury or property damage. The qualified
agency performing this work assumes responsibility
for the conversion.
-AWARNING:
The rangetop, as shipped from
the factorg, is set for use with its intended gas. If gou
wish to use gour rangetop with the alternate gas, gou
must first replace the orifices and convert the pressure
regulator.
-AWARNING:The
following adjustments
must be made before turning on the burner. Failure to
do so could result in serious injurg. Be sure pressure
regulator has been converted as described in Step 2.
TOOLS YOU NEEDED FOR CONVERSION
Crescent W rench
SafetyGlasses
1/2" Deepwell
SocketWrench
1/4" and7mm Nutdrivers
r_
SmallFlat-HeadScrewdriver
(2 to 2.4mm or 3/32" tip size,
60 mm long)
Philips
Small Pliers
Screwdriver
ORIFICE HOLDER
The range orifice holder
is located behind the front
access panel at the bottom
of the range.
The rangetop orifice holder
BurnerOrifices
is located insidethe range insulation cover.
Additional orifices may be present. Use onlg the orifices
specified in the instructions for gour range or rangetop.
Griddle
Grill
Orifice
Orifice
CONVERT THE REGULATOR
Disconnect
all electrical
power at the main circuit
breaker
or fuse box.
A. Removethe rear vent
RangeRegulator
trim (on ranges onlg)
to access the
regulator. The .
Rangetop.regulator is
on the left bottom
corner.
B. Shut offl_he gas supplLIbg closing the manual shut-off
va ve in the unit or at the wall.
C. Convertthe pressureregulator:
• Unscrew the cap with plunger.
• Placeyour thumb against flat side of the plunger and
press down to snap the plunger out at the cap.
• Carefullg look at the plunger to locate the NAT
or LPposition.
• Turn the
plunger
over so
that the
desiredgas
is showing
nearthe
bottom.
Cap
G, asket
@=/@
_
_--IPlunger
.....
Position _
LPPosition
Pressure R egulator
• Snap the plunger back into the cap.
• Screw the cap back onto the regulator.
_-I
CHANGE BURNER ORIFICES
INSTALLATION TIP:First remove all
orifices and then start replacing them.
This will help to prevent the possibilitg
that some mag not be replaced.
A.
B.
BurnerCap
Burner
Removethe burner grates,
Head
burner caps and burner heads.
Loosenthe top burner
Spark __
orifices using a 7 mm
Igniter
nut driver. Use small
pliers to carefullg lift out the orifices.
BurnerBase
The main orifice is located
low in the center of the
burner,while the simmer
orifice is located higher
beside the center
of the burner.
Main
Orifice
Orifice
21
loading