2. TECHNICAL SPECIFICATION

Max. operating air/fluid pressure: 12 bar (175 PSI)
Noise Level (LAeqT)*:
Weight g (lbs):
*Measuring point: 1m backwards from gun, 1.6m height.

2.1 TECHNICAL DATA

WS-200SP
NOZZLE
Split Nozzle
ORIFICE (mm)
WS-200SP-0801
0.8
WS-200SP-1001
1.0
WS-200SP-1201
1.2
WS-200SP-1401
1.4
WS-200SP-1601
1.6
WS-200SP-1801
1.8
WS-200FT
NOZZLE
Flat Tip Nozzle
ORIFICE (mm)
WS-200FT-0801
0.8
WS-200FT-1001
1.0
WS-200FT-1201
1.2
WS-200FT-1401
1.4
WS-200FT-1601
1.6
WS-200FT-1801
1.8
WS-200FT-0802
0.8
WS-200FT-1002
1.0
WS-200FT-1202
1.2
WS-200FT-1402
1.4
WS-200FT-1602
1.6
WS-200FT-1802
1.8
This manual is an integral part of pressure spray gun and must to be read carefully before starting
ANY ACTIVITY involving the use, adjustment and maintenance of the equipment, including its handling.
This manual must be stored in a safe place for any future reference.
Be sure to observe warnings and cautions in this instruction manual.
If not, it can cause paint ejection and serious bodily injury by drawing organic solvent.
This ANEST IWATA pressure spray guns complies to ATEX regulations 2014/34/EU.
Protection level: II 2 G X Suitable for using Zones 1 and 2.
X marking: Any static electricity should be discharged from the spray gun and needs to be diverted to
the ground via a conductive air hose not included.
HAZARD LEVEL
POTENTIALLY
HAZARDOUS SITUATION
82.9 dB(A)
395 (0.87)
AIR CAP SET
AIR PRESSURE
MARK
at Gun Inlet (MPa)
WS-200SP-01
AIR CAP SET
AIR PRESSURE
MARK
at Gun Inlet (MPa)
WS-200FT-01
WS-200FT-02
Air connection:
Fluid connection:
Max. Temperature range:
FLUID OUTPUT
(ml/min)
200
250
300
0.25
300
350
400
FLUID OUTPUT
(ml/min)
200
0.25
300
200
250
300
0.30
300
350
400
CONSEQUENCE
DEATH OR SERIOUS INJURY
MINOR TO MODERATE INJURY
PROPERTY DAMAGE
G1/4"
G3/8"
Atmosphere 5-40°C / Air-Fluid 5-43°C
AIR CONSUMPTION
PATTERN WIDTH
(l/min)
435
AIR CONSUMPTION
PATTERN WIDTH
(l/min)
380
475
EN
(mm)
210
230
240
240
255
265
(mm)
240
210
210
240
215
250
255
255
270
285
3