Persons using the unit must observe the standard safety regulations and read the certificate to prevent incorrect operation or misuse of
the unit.
The following additional safety regulations must also be observed:
- The unit must not be opened within the Ex-area.
- The batteries must only be changed outside the Ex-area.
- Additional or spare batteries must not be carried in the Ex-area.
- Only approved battery types may be used.
- Only spare sealing rings and discs of the manufacturer are allowed.
- Only accessories approved by the manufacturer may be used.
- Prevent the unit from coming into contact with aggressive acidic or alkaline solutions.
- Do not open the inside torch head.
- Storing of the torch is prohibited!
- After changing the batteries or the sealing rings always check to make sure that the sealing rings and threads are clean and in good
condition.
- Before using the lamp in the Ex-hazardous area and in order to ensure the IP rating, please check that all parts of the unit are hand
tightened up to the stop – being careful not to over-tighten.
Caution! Strong light may blind other people.
- Do not look directly into the light.
- Do not shine the light directly into the eyes of other people.
EC-type examination certificate no.: ZELM 05 ATEX 0272 X:
Ex-designation:
Approved for Zones 2, 1 and 0, device group II, potentially explosive gases of gas group C, vapours or mist, and temperature class T4.
Approved for Zones 22, 21 and 20, device group II, potentially explosive dusts, and T130 °C
The certification assures, that the maximum malfunction-surface-temperature of maximum 80% of the temperature class T4 / 130° C is
taken into consideration (acc. to EN 1127-1).
Ambient temperature Ta:
Storage temperature:
battery / power supply:
Lamp:
Operating time:
Dimensions:
Weight:
IP rating:
ESD protection:
CE designation:
Table of approved battery types
4.1 Special requirements for use in ex-hazardous areas
Manufacturer
Eveready
Duracell
Panasonic
Energizer
4. Safety regulations
5. Safety instructions
6. Ex-data
ZELM 05 ATEX 0272 X
II 1G Ex ia op is IIC T4
II 1D iaD 20 T130 °C
7. Technical data
-20 ... +50 °C
-30 ... +60 °C (without batteries)
3 x LR14 (see table)
1 high-performance LED (3-watt)
> 48 hours (continuous)
approx. 220 mm x 40/45 mm
approx. 550 g (including batteries)
IP 65
Antistatic housing
0102
Type
Energizer N° E93
Procell MN1400 LR14
Powermax 3 LR14
Powerline Industrial Battery LR14
Ucar Gold LR14
-13-