Ref. 1805M28B
Using this procedure the R.F. transmitter can be assigned to the motor.
1. Keep for 4 sec the button on the head motor. The motor takes an up and down step and emits one beep.
2. Press twice the "P2" button of the trasmitter. The motor emits one beep to every pression.
3. Press once the "▲" button of the trasmitter for to turn the motor clockwise. The motor emits 3 beep.
The transmitter is assigned.
During this procedure the time between two commands cannot be over 10 sec. If this time is higher, the
motor automatically exits of the procedure and he recovers the parameters previously set.
This procedure erase the transmitters and the limit stops memorised in the motor.
It is advisable to monitor the behaviour of the motor during calibration because if it
does not stop at a limit switch, the bottom rail could jam against the ceiling or in the
shutterbox, thereby damaging the system.
Pay attention to the position that the system reaches.
Any impact or sticking may permanently damage the system.
Periodically check that the limit stops are in the correct position.
The factory setting for the tubular motors Ref. 1805M28B and Ref. 1805M35B is such that a certain travel value
is in any case set. Using this procedure for setting the limit stops:
1. Press once the "P2" button. The motor takes an up and down step and emits 1 beep.
2. Press once the "▲" button. The motor takes an up and down step and emits 1 beep.
3. Press once the "P2" button. The motor takes an up and down step and emits 1 beep.
4. Run the motor with "▼" button.
5. When the blind reaches the position where you want to set the LOWER limit stop, press the "▬" button to
stop the motor. The motor emits 1 beep.
6. Run the motor with button "▼" or "▲" to correct the position.
7. Press 5 times the "▬" button, the motor emits one beep to every pression and memorises the LOWER
limit stop.
8. Run the motor with "▲" button.
9. When the blind reaches the position where you want to set the UPPER limit stop, press the "▬" button to
stop the motor. The motor emits 1 beep.
10. Run the motor with button "▼" or "▲" to correct the position.
11. Press 5 times the "▬" button, the motor emits one beep to every pression and memorises the UPPER limit
stop.
Note:
•
It isn't possible to set in the same position the both limit stops.
•
During the "Setting of limit stops" procedure, every time that the "▬" button is pressed, the motor emits
one "beep".
•
During the "Setting of limit stops", when the motor is moving if you press once the P2 button, the motor will
be moving "step by step". If press once P2 button again, the motor go back to run normaly. Use the "step by
step" function if it's necessary adjusted with precision the positions of limit stops.
•
Once activated, there are 2 min to complete the procedure. If after 2 min the procedure has not been
completed, the motor comes out of the procedure, erasing the limit switches and if he'll receive command,
he will move indefinitely. To set again the limit switchs, you repeat the procedure "Adjusting the limit
switch" from point 1.
Ref. 1805M35B
Assigning R.F. Transmitter
Setting of limit stops
Ref. 5143 - 5155
3