Fronius RI FB Inside/i Manual De Instrucciones página 26

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 35
Set node address
with dip switch
(example)
The node address is set with positions 1 to 6 of the dip switch.
The configuration is carried out in binary format. This results in a configuration range of 1
to 63 in decimal format
NOTE!
After every change of the configurations of the dip switch settings, the interface
needs to be restarted so that the changes will take effect.
(Restart = interrupting and restoring the power supply
or executing the relevant function on the website of the power source)
26
Dip switch
8
7
6
5
-
-
OFF
OFF
-
-
OFF
OFF
-
-
OFF
OFF
-
-
ON
ON
-
-
ON
ON
4
3
2
OFF
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
ON
ON
ON
ON
ON
OFF
ON
ON
ON
ON
1
Node address
1
2
3
62
63
loading