17. ASSISTANCE
To keep the tool in good condition, it is
recommended to service the tool and replace
worn parts on a regular basis.
require these services or spare parts, please
contact us directly:
BRALO, S.A. Milanos, 12. Pol. Industrial. La
Estación 28320 Pinto (Madrid) SPAIN
Telephone: +34 91 692 8285
18. GUARANTEE
The warranty is valid for 12 months from the
invoice purchase date.
The guarantee only covers defects in the parts or
their assembly.
Damage to the tool caused by the following
cases is not covered by the warranty:
19. MOST COMMON PROBLEMS
PROBLEMS AND CAUSES
SEVERAL TRIGGER PULLS ARE NECESSARY TO SET THE RIVET
Low air pressure.
Excessive lubrication at the air inlet
Broken or worn jaws.
There is air in the oil or the oil level in the oil tank is low Refill the oil tank.
RIVETER DOES NOT GRIP THE RIVET STEM CORRECTLY
The jaws are broken or dirty.
The jaw clamp is loose.
The nosepiece spring is broken or loose.
The parts have been incorrectly positioned or there is a
wrong part.
RIVETING MACHINE DOES NOT BREAK THE STEM
Insufficient air pressure.
Stem length is incorrect for the application.
There is little oil.
The air outlet is dirty.
THE MACHINE TAKES LONGER TO RIVET
Low air flow
EN
- Transport.
- Operator usage errors.
- Errors in maintenance work.
- Breakages or failures that are not attributed to
Should you
manufacturing defects.
- Normal wear and tear on consumable parts.
The warranty is invalid if tool components
are replaced without authorisation or if worn
parts other than those recommended by the
manufacturer are replaced, which could cause
damage to the tool.
BRALO assumes responsibility for manufacturing
defects, but is not liable if the operator does not
follow the instructions given in this manual.
The tool is built according to the European
Directive in force when the riveting tool is
marketed.
21
HT-40
SOLUTION
Increase air pressure.
Pour oil into the air inlet.
Replace the jaws.
Replace jaws or clean them.
Tighten the jaw clamp.
Replace the spring.
Identify the wrong parts.
Check air pressure or air leaks.
Replace the rivet.
Fill the oil tank.
Clean the air outlet.
Check flow rate and hose.
www.bralo.com