Table 3.1 Technical data
Model
Lift capacity
Pressure relief valve
Stroke cylinder
Electrical power
Mains power supply
380/415 V, 50 Hz
220/240 V, 50 Hz
220/240 V, 50 Hz single phase
Mains fuse
380/415 V, 50 Hz
220/240 V, 50 Hz
220/240 V, 50 Hz single phase
Control voltage
Hose break valve adjustment
Raising and lowering time
3 phases
Raising and lowering time
1phase
Noise level
Setting up
Dead weight
Operating temperature
Operating instructions (Version B)
Technical data
For general technical data also refer to the type plate on the vehicle lift.
ST 4032
3200 kg
260 bar (factory sealed with plastic
cap)
1870 mm
1745 mm (S-version)
3,6 kW
3 x phase, 1 x earth, 1 x neutral
3 x phase, 1 x earth
1 x phase, 1 x neutral, 1 x earth
3 x 16 A (slow-acting)
3 x 16 A (slow-acting)
1 x 16 A (slow-acting)
24 V direct current
28 l/min (1,25 mm)
24 / 23 s
47 / 23 s
max. 74 dB(A)
Indoor
900 kg
-15 -> +50 D.C.
30
ST 4040
4000 kg
260 bar (factory sealed with plastic
cap)
1870 mm
1745 mm (S-version)
3,6 kW
3 x phase, 1 x earth, 1 x neutral
3 x phase, 1 x earth
1 x phase, 1 x neutral, 1 x earth
3 x 16 A (slow-acting)
3 x 16 A (slow-acting)
1 x 16 A (slow-acting)
24 V direct current
28 l/min (1,25 mm)
29 / 29 s
59 / 29 s
max. 74 dB(A)
Indoor
910 kg
-15 -> +50 D.C.
ST 4032 / ST 4040