Power
Supply Cord Kit (U.S.A.)
The user is responsible for connecting the power supply
cord to the connection block located behind the back
panel access
cover.
This appliance may be connected by means of
permanent "hard wiring" (flexible armored or
nonmetallic
shielded copper cable), or by means of a
power supply cord kit. Use only a power supply cord kit
rated at 125/250 volts minimum and marked for use
with ranges. Cord must have either 3 or 4 conductors.
Terminals on end of wires must either be closed loop or
open-end spade lugs with upturned ends. Cord must
have strain relief clamp.
A 3-wire* or 4-wire single phase 120/240 or 120/208
Volt, 60 Hz AC only electrical supply is required on a
separate circuit fused on both sides of the line (time-
delay fuse or circuit breaker is recommended). DO NOT
fuse neutral. The fuse size must not exceed the circuit
rating of the appliance specified on the nameplate.30"
Range: Use a circuit breaker of 20 Amp; 36" Range:
Use a circuit breaker of 30 Amp.
* For mobile homes, new installations, recreational
vehicles, or areas where local codes do not permit
grounding through neutral, a 4 conductor power
supply cord kit rated at 125/250 volts and marked
for use with ranges should be used (see Figure 10).
I Factory
Connected
Power
Supply Cord (Canada only)
Your range is equipped with a factory-connected
power
cord (see Figure 3). Cord must be connected to a
grounded 120/240 volt or 120/208 volt range outlet. If
not outlet is available, have one installed by a qualified
electrician.
Figure 3
E!
Junction
Box or Wall
Receptacle
Location
Suggested
location
of the junction
box or wall
receptacle is showed in Figure 4 for 30" Range and
on figure 5 for 36" Range. It can also be located in
the lower left corner of the adjacent
right cabinet
(see Figure
6). If a service
cord is used, the wall
receptacle
should be located in accordance
with the
dimensions below.
Center
Line of
Range
I0"
I
(25.4 cm)
vvALL
7" Max.
(17.8 cm Max.)
I
.....
Locate EFectricd Hook-up
_
Center
....
Inside Shaded Area
Line of
Range
30" Range Junction Box or Wall Receptacle Location
Figure 4
Center
Line of
Range
I0"
(2 5.4 crn)
_
5" Max.
J-
1(12.7 cm Max.)
_A/ALL
I
I_
r
I
_
v,
I
I
I
/-
Locate
Electrical
Hook-up
jl_o_
-
_
Inside Shaded Area
J_
_
Center
Line of
Range
36" Range Junction Box or Wall Receptacle Location
Figure 5
Figure 6
Electrical
Shock Hazard
• Electrical
ground
is required
on this appliance.
• Do not connect
to the electrical
supply until
appliance
is permanently
grounded.
• Disconnect
power
to the circuit
breaker or fuse
box before
making the electrical
connection.
• This appliance
must be connected
to a
grounded,
metallic,
permanent
wiring
system,
or a grounding
connector
should
be connected
to the grounding
terminal
or wire lead on the
appliance.
• Do not use the gas supply line for grounding
the appliance.
Failure to do any of the above could result in a
fire, personal
injury or electrical
shock.
4