Problem
and
appear simultane‐
ously.
You hear a beep sound, the indi‐
cators above
blink and
SenseBoil® does not start.
SenseBoil® does not work.
and a number come on.
9.2 If you cannot find a solution...
If you cannot find a solution to the problem
yourself, contact your dealer or an Authorised
Service Centre. Give the data from the rating
plate. Give also three digit letter code for the
glass ceramic (it is in the corner of the glass
surface) and an error message that comes
10. TECHNICAL DATA
10.1 Rating plate
Model I84AV423FB
Typ 62 D4A 01 AA
Induction 7.2 kW
Ser.Nr. .................
AEG
88
ENGLISH
Possible cause
There is too much or too little water
in the pot.
You boiled some food other than wa‐
ter and potatoes. The boiling point
was moved in time and SenseBoil®
could not work properly.
None of the cooking zones is ready
to be used with SenseBoil®. There
is some residual heat on the cooking
zones you want to choose or they
are still in use.
The power level of the hob is too
low.
There is an error in the hob.
on. Make sure, you operated the hob
correctly. If not the servicing by a service
technician or dealer will not be free of charge,
also during the warranty period. The
information about guarantee period and
Authorised Service Centres are in the
guarantee booklet.
PNC 949 597 993 00
220 - 240 V / 400 V 2N, 50 / 60 Hz
Made in: Germany
7.2 kW
Remedy
Only boil water and potatoes with the
use of SenseBoil®. Refer to "Hints and
Tips".
Finish your previous cooking activities
and choose a free cooking zone with‐
out any residual heat.
Set the power level to a higher value.
Make sure that the selected power fits
the house installation fuses. Refer to
"Before first use" > " Power limitation".
Deactivate the hob and activate it
again after 30 seconds. If
on again, disconnect the hob from the
electrical supply. After 30 seconds,
connect the hob again. If the problem
continues, speak to an Authorised
Service Centre.
comes