PROBLEM
CAUSE
CORRECTION
Motor will not
Motor overload
protection
run.
switch
has tripped.
Tank pressure exceeds
pressure switch "cut-in"
pressure.
Let motor cool off and
overload
switch will
automatically
reset.
Motor will start automatically
when tank pressure drops
below "cut-in"
pressure of
pressure switch.
Extension
cord is wrong
Check for proper gauge wire
length or gauge,
and cord length.
Check valve stuck open.
Remove and clean, or replace.
Loose electrical
connections.
Check wiring connection
inside pressure switch and
terminal
box area.
Have checked
by a Trained
Service Technician.
Possible defective
motor or
starting
capacitor.
Paint spray on internal motor
parts.
Pressure release valve on
pressure switch has not
unloaded
head pressure.
Fuse blown, circuit breaker
tripped.
Have checked
by a Trained
Service Technician.
Do not
operate the compressor
in
the paint spray area. See
flammable
vapor warning.
Bleed the line by pushing
the
lever on the pressure switch to
the "Off" position;
if the valve
does not open, replace switch.
1.
Check fuse box for blown
fuse and replace as
necessary.
Reset circuit
breaker. Do not use a
fuse or circuit breaker
with higher rating than
that specified
for your
particular
branch circuit.
2.
Check for proper fuse.
You should use a time
delay fuse.
3.
Check for low voltage
conditions
and/or
proper
extension
cord.
4.
Disconnect
the other
electrical
appliances
from
circuit or operate the
compressor
on its own
branch circuit.
21- ENG
NO15838
loading