EN
Installation for boiler or heat pump:
Connect the blue and brown cable to your
receiver's COM/NO terminal blocks; polarity
is not applicable.
Connect the other end of the cable to your heating
system, on the COM & NO terminal blocks. (if you
have a bridge on your heating system, please remove
it). Then take the second cable, and connect the
brown wire to L (live), and the blue wire to N (neutral).
Connect the other end of the cable to your heating
system, on the L or P terminal blocks for brown, and
N for blue. Make sure to leave the receptor's switch on
the AC OFF position.
Installation for boiler or heat pump with hot
water tank.
Y-plan :
Connect the blue and the brown cable to your HW ON and
CH ON. Connect the other end of the cable to your heating
system on the COM, and the other end to the W on your
valve.
Then take the second cable, and connect the brown wire to L
(live), and the blue wire to N (neutral). Connect the other end
of the cable to your heating system, on the L or P terminal
blocks for brown, and N for blue. Make sure to leave the
receptor's switch on the AC OFF position.
12
Copyright
2020 SOMFY ACTIVITES SA, Société Anonyme. All rights reserved.
©
CH
CH
ON
COM
NO
AC
Brown
OFF
Radio receiver
L
N
Brown
Blue
Blue