To add another transmitter to the actuator it is necessary to use a remote control previously programmed
transmitter and proceed as follows:
A R6 control only: press the key SELC of the already programmed transmitter repeatedly, until displayed by
the led the selected channel
B Set the dip-switches no.1 into ON position of both transmitters
C Press and hold for 15 seconds the key PROG of the transmitter 1 already programmed
D Release the key PROG of transmitter 1
E Within 5 seconds press and hold for 5 seconds the key PROG of the transmitter 2 to be programmed
F Set the transmitter dip-switch no. 1 of transmitters 1 and 2 into OFF position
G Wait 10 seconds
H Pressing the keys UP or DOWN the actuator moves in opening/closing direction
5.2.DIP-SWITCH 3: DELETION OF ALL THE STORED TRANSMITTERS
To delete all the transmitters stored on the actuator it is necessary using a remote control previously
stored and proceed as follows:
A Power only the actuator to be reset
B R6-CONTROL only: press the key SELC on the transmitter repeatedly until displayed the channel stored
(by the leds)
C Set the transmitter dip-switch no.3 into ON position
D Press and hold for at least 10 seconds the key PROG of the transmitter
E Leave the key PROG and set the remote dip-switch no.3 into OFF position
28