If two or more Bus waveforms are displayed, pushing the button cycles through selecting each Bus waveform.
5.
Horizontal controls:
Position moves the waveform and graticule side to side on the screen (changing the trigger point position in the waveform
record). Push the knob to center the trigger event to the center graticule on the Waveform view.
Scale sets the time per major horizontal graticule division and samples/second parameters for the oscilloscope. Scale applies to
all waveforms. Push the knob to enable the Fine mode for making smaller increment changes. Push the knob again to exit Fine
mode.
Zoom opens the Zoom mode. Push Zoom again to close zoom mode.
Zoom knob (center knob) increases or decreases the area of the zoom box in the Zoom Waveform Overview, which in turn
controls the zoom amount of the waveforms shown in the main Zoom view.
Pan knob (outer knob) moves the Zoom box left or right in the Zoom Waveform Overview, which in turn controls the part of the
waveform shown in the main Zoom view.
Navigate (left and right arrow) buttons puts the oscilloscope in Zoom mode and positions the previous or next search point in the
waveform record to the center graticule of the Waveform view. There must be a Search badge present in the Results bar before
the Navigate function will operate. Press and hold a front panel navigate button to continue moving to the next search point in
that direction.
The front panel Navigate buttons can also be used for the Previous and Next button functions on measurement badges.
6.
Miscellaneous controls:
Touch Off turns touch screen capability off. The Touch Off button is lighted when the touch screen is turned off.
Save is a one-push save operation that uses the current File > Save As settings to save screen shots (including open menus
and dialog boxes), waveform files, instrument settings, and so on.
If a File > Save or File > Save As operation has occurred since the last instrument startup, pushing Save saves the file types
to the location last set in the Save As configuration menu.
If no file save operation has occurred since the last instrument startup, pushing Save opens the Save As configuration menu.
Select a tab to select the type of file to save (Screen Capture, Waveform, and so on), set any associated parameters, and
where to save it, and select OK. The specified file or files are saved. The next time you push Save, the same type files are
saved.
Screen Captures capture the entire screen, including most displayed configuration menus and dialog boxes.
Default Setup restores the oscilloscope settings (horizontal, vertical, scale, position, and so on) to the factory default settings.
Autoset automatically displays a stable waveform.
7.
Ground and Probe Compensation connectors: The Ground and Probe Compensation connectors are located at the lower right side
of the instrument, near the front panel. The Ground connector (the small hole in the case) provides an electrically grounded (through
4 Series B Mixed Signal Oscilloscopes MSO44B and MSO48B Quick Start Manual