N
Performing
repairs may expose voltage
sources,
moving
parts or compressed
air sources,
moving parts or
compressed
air sources.
Personal
}njury may occur. Prior to attempting
any repairs, unpBug the a}r compressor
and Heed off aH air tank a}r
pressure.
PROBLEM
CORRECTION
Excessive
tank
pressure
- safety
valve
pops off.
Air Ieaks at
fittings.
Air leaks at or
inside check
valve.
Air leaks at
pressure switch
release valve.
Air leaks in air
tank or at air
tank welds.
CAUSE
Pressure switch does
not shut off motor when
compressor
reaches "cut-
out" pressure.
Pressure switch "cut-out"
too high.
Tube fittings are not tight
enough.
Check valve seat damaged.
Defective pressure switch
release valve.
Defective air tank.
Leaking sea!.
Air leaks
between head
and valve plate.
Move On/Auto/Off
lever to
the "Off" position,
if the unit
does not shut off contact a
Trained Service Technician.
Contact a Trained Service
Technician.
Tighten fittings where air
can be heard escaping.
Check fittings with soapy
water solution. Do Not
Overtighten,
A defective check valve
results in a constant air leak
at the pressure release valve
when there is pressure in the
tank and the compressor
is shut off. Reptace check
valve. Refer to the "To
RepIace or Clean Check
Valve" in the "Service and
Adjustment"
section.
Contact a Trained Service
Technician.
Air tank must be replaced.
Do not repair the leak.
Do not drill
into, weld or
otherwise
modify air tank
or it will weaken,
3"he tank
can rupture
or explode,
Contact a Trained Service
Technician.
21-ENG
A09708
loading