Hansgrohe Vernis Blend Showerpipe 200 1jet 26276 Serie Modo De Empleo/Instrucciones De Montaje página 2

Ocultar thumbs Ver también para Vernis Blend Showerpipe 200 1jet 26276 Serie:
Safety Notes
Gloves should be worn during installation to prevent crushing and cutting
injuries.
The product may only be used for bathing, hygienic and body cleaning
purposes.
The arm of the shower head is intended only to hold the shower head. Do not
load it down with other objects!
Children as well as adults with physical, mental and/or sensoric impairments
must not use this product without proper supervision. Persons under the
influence of alcohol or drugs are prohibited from using this product.
Do not allow the streams of the shower touch sensitive body parts (such as your
eyes). An adequate distance must be kept between the shower and you.
The product may not be used as a holding handle. A separate handle must be
installed.
The hot and cold supplies must be of equal pressures.
Installation Instructions
• Prior to installation, inspect the product for transport damages. After it has been
installed, no transport or surface damage will be honoured.
• The pipes and the fixture must be installed, flushed and tested as per the
applicable standards.
• The plumbing codes applicable in the respective countries must be observed.
• The installation dimensions stated in these installation instructions are ideal for
people of approximately 1800 mm in body height. The dimensions can be
altered if required. In this case, pay attention to the fact that a change of
installation height will also change the minimum height, and that the altered
mounting dimensions must be taken into consideration.
• During installation of the product by qualified trained personnel, make sure that
the entire fastening surface is even and smooth (no protruding seams or tile
offset), that the finish of the wall is suitable to apply the product and has no
weak points.
• The premounted dirt collection screen must be used to prevent dirt from entering
through the pipes. Dirt entering can affect the function and/or lead to damage
to the functional components of the fitting. Hansgrohe will not be held liable for
any resulting damage.
• The product is not designed to be used with steam baths!
• If the continuous water heater causes any problems, or you have different water
pressures you must install a water limiter to the cold supply, (ordered separate-
ly,article number 97510000).
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
Hot water temperature:
Centre distance:
Connections G 1/2:
• Safety against backflow
• The product is exclusively designed for drinking water!
Symbol description
Do not use silicone containing acetic acid!
Fault
Insufficient water
Crossflow, hot water being forced into cold water
pipe, or vice versa, when mixer is closed
Spout temperature does not correspond with
temperature set
Temperature regulation not possible
Instantaneous heater didn't work with thermostat
4
English
The desired maximum temperature for example max. 42º C can be pre-set thanks
to the safety function.
After the installation, the output temperature of the thermostat must be checked. A
correction is necessary if the temperature measured at the output differs from the
temperature set on the thermostat.
Thermal disinfection pursuant to process sheet DVGW W 551 (≥ 70°C / > 3 min)
must only be carried out by qualified personnel.
• The check valves must be checked regularly according to EN 806-5 in
• To guarantee the smooth running of the thermostat, it is necessary from time to
Special accessories (see page 40)
order as an extra
To empty the overhead shower after use, hold it in a slightly inclined position.
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
max. 60°C
150±12 mm
cold right - hot left
Cause
- Supply pressure inadequate
- Regulator filter dirty
- Shower filter seal dirty
- Backflow preventers dirty or leaking
- Thermostat has not been adjusted
- Hot water temperature too low
- thermo cartridge calcified
- Filters are dirty
- check valve hasn't moved back
- Flow limiter in handshower isn't removed
Assembly (see page 32)
Safety Function (see page 34)
Adjustment (see page 33)
Thermal disinfection (see page 34)
Maintenance (see page 42)
accordance with national or regional regulations (at least once a year).
time to turn the thermostat from total hot to total cold.
Dimensions (see page 36)
Flow diagram (see page 36)
Overhead shower
Hand shower
Spare parts (see page 40)
XXX = Colors
000 = Chrome Plated
670 = Matt Black
• tile-matching-disk #93813XXX
• extension 100 mm #94164XXX
• pipe 945 mm #93770XXX
• pipe 1145 mm #93907000
Cleaning (see page 38)
Operation (see page 35)
Test certificate (see page 44)
Remedy
- Check water pressure (If a pump has been installed
check to see if the pump is working).
- Clean filter in front of the mixer and on the MTC-ther-
mo cartridge
- Clean filter seal between shower and hose
- Clean backflow preventers, exchange if necessary
- Adjust thermostat
- Increase hot water temperature to 42 ºC to 60 ºC
- Exchange thermo cartridge
- Clean the filter / exchange filter
- Exchange check valves
- Remove flow limiter
loading