Air Compressor Pump (not shown):
Compresses air into the air tank.
Working air is not available until the
compressor has raised the air tank
pressure above that required at the
air outlet.
Check Valve:
When the air
compressor is
operating, the
check valve is
"open",
allowing
compressed air to enter the air tank.
When the air compressor reaches
"cut-out" pressure, the check valve
"closes", allowing air pressure to
remain inside the air tank.
HOW TO STOP
1.
Set the On/Auto/Off lever to
"OFF".
BEFORE FIRST START-UP
following break-in instructions are
not closely followed.
This procedure is required before the
air compressor is put into service
and when the check valve or a
complete compressor pump has
been replaced.
1.
Make sure the On/Auto/Off lever
is in the "OFF" position.
NOTE: Pull coupler back until it
clicks to prevent air from escaping
through the quick connect.
2.
Plug the power cord into the
correct branch circuit receptacle.
(Refer to Voltage and Circuit
Protection paragraph in the
Installation section of this
manual.)
3.
Open the drain valve fully
(counter clockwise) to permit air
to escape and prevent air
pressure build up in the air tank
during the break-in period.
NOTE: Always drain tank on a
washable surface or in a suitable
container to prevent damaging or
staining surfaces.
Check Valve
Serious damage
may result if the
4.
Move the On/Auto/Off lever to
"ON/AUTO" position. The
compressor will start.
5.
Run the compressor for 15
minutes. Make sure the drain
valve is open and there is
minimal air pressure build-up in
tank.
6.
After 15 minutes, close the drain
valve (clockwise). The air receiver
will fill to "cut-out" pressure and
the motor will stop.
The compressor is now ready for use.
BEFORE EACH START-UP
1.
Place On/Auto/Off lever to
"OFF".
2.
Pull regulator knob out, turn
counter clockwise until it stops.
Push knob in to lock in place.
3.
Attach hose and accessories.
NOTE: The hose or accessory
will require a quick connect plug
if the air outlet is equipped with a
quick connect socket.
causes a hazardous risk of
bursting. Check the manufacturer's
maximum pressure rating for air
tools and accessories. The
regulator outlet pressure must
never exceed the maximum
pressure rating.
HOW TO START
1.
Turn the On/Auto/Off lever to
"AUTO" and allow tank pressure
to build. Motor will stop when
tank pressure reaches "cut-out"
pressure.
2.
Pull the regulator knob out and
turn clockwise to increase
pressure. When the desired
pressure is reached push knob in
to lock in place. The compressor
is ready for use.
NOTE: Always operate the air
compressor in well-ventilated areas
free of gasoline or other combustible
vapors. If the compressor is being
used to operate a sprayer DO NOT
place near the spray area.
13- ENG
Too much air
pressure
D26119