open time, and the duration until returning to automatic
mode
You can also change this temperature at any time that
the open window mode is activated by turning the rotary
selector and confirming with the confirm key.
Note: To disable this feature, set the duration time to 0.
- tOF. Drift temperature
Adjusts the margin of error between the valve
temperature and the actual room temperature.
Set the difference between the nominal and actual
temperature as follows. If the nominal temperature is
20ºC
- rES. Factory reset
Select the rES function, press confirm.
The display will show conf, if you press the confirm key
again at that time, the factory settings will be restored
and you will lose all your custom settings.
- POS. Valve position
Shows the valve opening as a percentage: 0% closed
and 100% open.
51