BST EKR 1500 Traducción Del Manual Original página 57

Sistema alineador de banda con sensores analógicos y ccd 2004
Ocultar thumbs Ver también para EKR 1500:
Start-up of the Actuator EMS 17 / EMS18
Connected to EKR 1500 / EKR 1000 / CCD Line Guider
1.
Requirements for Start-up
1.1
Set DIL Switches
1.2.
Lay Jumpers
2.
Setup
2.1
Activate Manual Stroke Setup
+
2.2
Determine Sense of Motor Rotation
or
2.3
Setting of Stroke Limitation
Start-up EMS 17 / EMS 18
Start-up is carried out according to chapter 5 of the appropriate
operating manual. For the connection of the actuator EMS 17 /
EMS 18 the following additional adjustments have to be executed.
 S1.2 = OFF
 S1.5 = OFF
 Socket JX11: Set jumper "A"
 Socket JX10: Set jumper "DE"
 Press key "MAN" and hold it.
SET UP
 Press key "SETUP" in addition.
 Release both keys. The LED of the key "SETUP" is blinking and
the LED of the key "ENTER" is off.
Stroke setup is active.
 Press one arrow key.
 Observe guiding device!
The guiding device must move slowly in one direction. If the
guiding device moves on a stop, then change position of DIL
switch S1.3, from "ON" to "OFF" or vice versa.
Stroke setup is active.
1. Move the guiding device to the desired final position via one of
the arrow keys. The final position limits the guiding movement
in this direction.
EDV No.: MD.154.01.04
Date:
23.08.11
1/2