(2) Turn on the power switch to start heating. If you need to heat up quickly, adjust the power
switch to the highest power.
(3) When the room temperature meets your needs, you can adjust the thermostat back until
hear "click". At this time, the electrical oil heater will enter a constant temperature state and
the thermostat will operate as the temperature rises and falls.
INSTALLATION METHOD
*Installation method of casters:
1. Invert the electrical oil heater with bottom up.
2. Fix the caster board on the electrical oil heater body.
3. Install the casters on the baseboard.
4. After installation, turn the electrical oil heater over with casters on the ground and rest it
for 3 to 5 minutes before use. (The technology is under continuous improvement, no further
notice will be given if there are any changes.)
MAINTENANCE
1. External cleaning must be done after the switch is turned off, the power plug is unplug-
ged and the machine is cooled.
2. Do not use it in a high temperature environment or in an open flame to avoid discolora-
tion or deformation of the machine.
3. Clean and maintain as shown.
4. After cleaning and maintenance, put the parts into the packing box in the original pac-
kaging order.
5. When the machine is not in use, store it in a place with good dry and ventilated condi-
tions and avoid crushing and collision.
6. This machine only needs the general external cleaning and maintenance, namely, use
a soft cloth with a neutral detergent to remove dirt from the surface of the machine, and
then dry it with a dry cloth.
7. Do not rinse it directly with water.
8. Do not use thinner, toluene, acid lotion, lamp oil or chemical rag to avoid discoloration
or deterioration.
TROUBLESHOOTING GUIDE
Possible operating anomalies
INCIDENT
CAUSE
SOLUTION
Switch on the appliance
Appliance not switched on.
using the speed button.
The device
does not
The unit is on but the selected
Increase the temperature
work.
temperature level in the thermostat is
level of the thermostat
lower than the temperature of the room.
(D)