instruction manual
8. Do not walk or stand on the compressor or its components.
1.3 Safety precautions during installation
The manufacturer declines any responsibility whatsoever for damages or injuries
that may derive through failure in observing these precautions or normal caution
and through failing to provide the required attention for the installation, operation,
maintenance and repairs, even if not expressly quoted
Precautions during installation
1. The machine must be lifted by exclusively using suitable equipment, conforming to the applicable
safety regulations. Loose or rotating components must be safely secured before hoisting operations
are carried out. It is strictly forbidden to stop or stand in the risk area below suspended loads. Hoisting
acceleration or deceleration must be maintained within safety limits. A safety helmet must be worn
when working in an area with overhead or hoisting equipment.
2. Place the machine in an area where the ambient air is as fresh and clean as possible. If necessary,
install a suction conduit. Do not obstruct air vents. Utmost attention must be paid to reducing to the
minimum the possibility of humidity being introduced together with the intake of air.
3. Before connecting any pipes, all blind flanges, plugs, covers and hygroscopic substance sachets
must be removed.
4. Air flexible hoses must be of the correct dimensions and must be suitable for the operating pressure
exercised. Never utilise worn, damaged or perished flexible hoses. Dimensions of the distribution
pipes and connections must be correct and suitable for the operating pressure.
5. Intake air must be free of smoke, vapours and flammable particles, such as those from paint solvent,
which could cause a fire to ignite or an internal explosion.
6. Set up the intake air vent so that there is no risk of wide garments being sucked in.
7. Ensure that the exhaust pipe connecting the compressor to the end refrigerator or the compressed
air network can expand with the heat and that it will not be in contact with or in proximity of flammable
material.
8. No external force must be exercised on the air outlet valve: The connected pipe must not be subjected
to stresses.
9. If a remote control is installed, the machine must have a clearly visible notice indicating: DANGER:
10. The machines must be installed in a way that ensures that there is a suitable cooling air flow availa-