INSTALLATION
1
REQUIRED TOOLS
Set of screwdrivers
Fixed wrenches
Socket wrench (8 mm)
Set of Allen keys
Lubrication grease (graphite or lithium grease)
2
INITIAL CONDITIONS AND CHECKS
Initial conditions of the gate
Check that the size of the gate is within the
admissible range of the operator (see the
technical features of the operator).
If the gate to be automated has a personnel
door, use a safety device to prevent the
operator from running with the personnel door
open.
The gate must have an opening and a closing
stopper.
Environmental conditions
This device is not suitable for installation in
inflammable or explosive environments.
Electrical power supply installation
The electrical connections must be made in line
with the instructions in the control board
manual.
The electrical cable section is indicated in: "Fig. 1
Elements of the complete installation" on page 43.
48
Installation Manual
Marker pencil
Spirit level
Tape measure
Welding machine
Use the welding machine in line with the user
manual.
The gate must be easy to handle manually, namely:
• It must be balanced, in order to ensure the effort
made by the motor is minimum.
• There should be no stiffness throughout its open/
close.
Do not install the operator in a gate which does
not work correctly in manual operation, as this
may lead to accidents. Repair the gate before
installing.
Check that the admissible environmental
temperature range for the operator is suitable
for the location.