CONTROL ACCESSORIES OPERATION
ATTENTION: ONLY IMPULSIVE COMMANDS HAVE TO BE CONNECTED.
Make sure that any other type of command accessories (e.g. mass detectors)
used on the installation are set in the IMPULSIVE mode, otherwise, the gate will
be operated even without the protection of the safety devices.
STEP-BY-STEP BUTTON (COM-K BUTTON)
DIP 6 OFF =>
It cyclically performs the commands open-stop-close-stop-open etc.
DIP 6 ON =>
Opens the gate when closed. There is no effect if activated while
opening. If activated when gate is open, the gate closes. If activated
while closing, the gate reopens.
OPEN BUTTON (COM-OPEN)
The button controls the opening movement when the gate is stationary. If activated while
closing, it reopens the gate.
CLOCK FUNCTION OF OPEN BUTTON
If you wish to use a TIMER (or simply a switch) to open and hold the gate
opened, you must request a T2 24V with firmware version fw 03 NOUP.
If the version if fw 03 or higher, BEWARE: IN CASE OF FAILURE OF THE SAFETY
DEVICES, A MINUTE AFTER THE TIMER OR THE SWITCH HAVE BEEN ACTIVATED,
THE GATE WILL OPEN WITHOUT ANY SAFETY PROTECTION!
This function is useful during peak hours, when vehicle traffic is slow (e.g. entry/exit
of workers, emergencies in parking or residential areas and, temporarily, for moving
operations).
CLOCK FUNCTION APPLICATION
It is necessary to request a T2 24V control panel with firmware 03 NOUP.
By connecting a switch and/or a daily/weekly clock (instead of or in parallel to the open
button N.O. "COM-OPEN"), you can open and keep the automation open for as long as
the switch is pressed or the clock remains active. Command functions are inoperative
with open automation.
Releasing the switch or at the preset time, the automation closes immediately.
CLOSE BUTTON (COM-CLOSE)
Controls the closing movement when the gate is stationary.
REMOTE CONTROL
DIP 6 OFF =>
It cyclically performs the commands open-stop-close-stop-open etc.
DIP 6 ON =>
Opens the gate when closed. There is no effect if activated while
opening. If activated when gate is open, the gate closes. If activated
while closing, the gate reopens.
PEDESTRIAN OPEN BUTTON (COM-PED.BUTT.)
Partial opening and closing control.
During pedestrian opening, pausing or closing, you can control the opening of any
command linked to the T2 24V board.
With DIP 6 you can choose the operation mode of the pedestrian push button.
DIP 6 OFF =>
It cyclically performs the commands open-stop-close-stop-open etc.
DIP 6 ON =>
Opens the gate when closed. There is no effect if activated while
opening. If activated when gate is open, the gate closes. If activated
while closing, the gate reopens.
ELECTRIC LOCK (LOCK)
Set DIP 8 to ON to enable control of the electric lock when opening.
ELECTRIC LOCK PULSE RELEASE IN OPENING
Set DIP 9 to ON to enable the electric lock pulse release when opening (provided DIP 8
is ON).
If a command to open the gate is given when the gate is closed, the closing movement is
performed for 0.5 seconds and the electric lock is simultaneously activated (followed by
a 0.5 second pause and then the opening of the gate).
ELECTRIC LOCK PULSE ENGAGEMENT
Set DIP 10 to ON to enable the pulse engagement of the electric lock when closing. Upon
closing, motors are activated for 0.5 seconds at full voltage to ensure lock engagement.
EASY MOTOR RELEASE
Set DIP 11 to ON to enable easy manual release (provided that DIP 10 is ON), upon
closing a reverse motion with a fixed time of 0.2 seconds occurs to facilitate manual
release.
OPERATION OF SAFETY ACCESSORIES
PHOTOCELL (COM-PHOT)
DIP 4 OFF =>
if an obstacle is placed in range of the photocells when the gate is
closed, the gate does not open. During operation, photocells work when
opening (by starting the opening movement only after the obstacle is
removed) and closing (by starting the reverse movement only after the
obstacle is removed).
DIP 4 ON =>
if an obstacle is placed in range of the photocells when the gate
is closed and the command to open is given, the gate opens (the
photocells do not work while opening). Photocells work only during
closing (with reverse motion restored after a second, even if they are
still engaged).
CONTROL OF IMMEDIATE CLOSING AFTER MOVEMENT IN FRONT OF PHOTOCELLS
DIP 16 ON and DIP 4 OFF => if photocells are engaged during opening, the gate
DIP 16 ON and DIP 4 ON =>
DIP 12 OFF => immediate closing after movement in front of the photocells is
deactivated.
N.B.: Please check photocell operation at least every six months.
EDGE (SAFETY STRIP) (COM-EDGE)
If engaged during opening, reverses the motion when closing.
If engaged when closing, reverses the motion when opening.
If it remains engaged again, it performs a further reversal after 2 seconds, then performs
an additional short reversal and then gives the sensor failure or engaged alarm (N.O.
contact).
If the sensor remains engaged (N.O. contact) no movement is allowed.
If not used, jump the terminals COM-EDGE.
MONITORING OF SAFETY SENSORS (A+ TEST A-)
Sensors can be monitored through the A+ TEST input and DIP 12 ON.
The monitoring consists of a functional test of the sensor run after every full gate opening.
Closing the gate is therefore permitted only if the sensors have passed the functional test
after each opening.
CAUTION: MONITORING OF THE SENSOR INPUT CAN BE ACTIVATED WITH DIP 12 ON OR
DEACTIVATED WITH DIP 12 OFF. IN FACT, THE FUNCTIONAL TESTING OF SENSORS IS
'POSSIBLE ONLY IF THESE DEVICES HAVE THEIR OWN POWER SUPPLY.
A MECHANICAL SENSOR CAN NOT BE MONITORED, SO DIP 12 SHOULD BE SET TO OFF.
SENSOR AUTOTEST ALARM (DIP 12 ON)
If the sensor fails the monitoring test after opening, an alarm is displayed by the blinker
lighting up. Gate closure is not allowed in this condition. Normal operation can be restored
only by repairing the sensor and pressing one of the activated controls.
STOP BUTTON (COM-STOP)
The STOP button stops the gate during any operation.
If held when the gate is fully open (or partially when using the pedestrian control)
automatic closing is temporarily deactivated (if activated by the TCA trimmer and LED DL6
on). It is therefore necessary to use a new command to make it close.
The automatic closing function is reactivated on the next cycle (if activated by the TCA
27
stops and the gate only closes one second after the
photocells are disengaged.
if photocells are engaged during opening, the gate
continues to open. Upon disengagement of the
photocells, the gate stops and reverses closing motion
after a one second pause.
If total opening is reached (end of opening time),
immediate closing is deactivated and automatic
time closing is activated (if TCA trimmer is
activated and LED DL6 is on). If during closing there
is a rapid movement (e.g. pedestrian) the gate will
open again for two seconds and then close once
again.
G