English
Application
Bus line rectifier for Siedle In-Home
bus: audio in switch panel housing
for power supply to the bus users.
Application
The line rectifier may only be used
exclusively to supply Siedle appli-
ances. Any other application is
deemed not in accordance with its
intended use and exonerates the
manufacturer from any liability.
Electrical voltage
• Mounting, installation and ser-
vicing work on electrical devices may
only be performed by a suitably
qualified electrician. Failure to
observe this regulation could result
in the risk of serious damage to
health or fatal injury due to electric
shocks.
• Operation at an altitude of up to
2000 m above sea level.
• Observe EN 62368-1!
In a building installation, an all-
pole mains switch with a contact
opening of at least 3 mm must be
provided. The device must not be
exposed to water drops or sprayed
water! Sufficient ventilation must be
ensured. Pay particular attention to
ensure that ventilation slots are not
covered.
• When using stranded cores as
cable material, these must be fitted
with wire end ferrules without fail.
Scope of supply
• Line rectifier for top hat rail
mounting
• This product information
Accessories
ZBVG 650-...: Is required in systems
with more than one line or for
programming the in-home bus via
a Windows PC (BPS 650-...) and
PRI 602-... USB. Only one unit
may be installed within the Siedle
In-Home bus.
Mounting
1 Clip the bus line rectifier onto the
top hat rail.
Terminal assignment
L1, N
Power connection
Ta, Tb
In-Home bus
Sa, Sb
System bus audio
b, c
Power supply 12 V AC
Tö, Tö
Relay contact door release
Li, Li
Relay contact light
Commissioning
Installation and commissioning are
described in the system manual.
The latest issue can be found in the
download area at www.siedle.com.
Specifications BNG 650-0
Operating voltage: 230 V AC,
+/-10 %, 50/60 Hz
Operating current: 200 mA
Output voltage: 27.5 V DC, 12 V AC
Output current: 0.5 A DC, 1 A AC
Fusing: primary fuse 1 T 250 mA L,
secondary short circuit proof
Contact type:
2 n.o. contacts 24 V, 2 A
Protection system: IP 30
Ambient temperature:
0 °C to +40 °C
Horizontal pitch (HP): 9
Dimensions (mm) W x H x D:
162 x 89 x 60
Specifications BNG 650-1
Operating voltage: 125 V AC
+/–10 %, 50/60 Hz
Operating current: 360 mA
Fusing: primary fuse 1 T 500 mA L,
secondary short circuit proof
For further technical specifications
see above
3