Technical Data
Model
Mains voltage / frequency
Nominal performance
Protection type
Suction port
Pressure port
1)
Max. flow rate (Q
)
max
Max. pressure
1)
Max. delivery height (H
)
max
Max. suction height
Volume of the pressure tank
Max. size of the solids being pumped
Max. permissible operating pressure
Min. ambient temperature
Max. ambient temperature
Min. fluid temperature
Max. fluid temperature (T
)
max
Max. cut-in frequency in one hour
Length of connection cable
Cable type
Weight (net)
Guaranteed sound power level (L
Measured sound power level (L
2)
Sound pressure level (L
)
pA
Dimensions (L x D x H)
Item no.
1)
The values were determined with free, unreduced in- an outlet.
2)
Noise emission values obtained according to the EN 12639 regulation. Measurement method according to
EN ISO 3744.
3)
Due to the factory pre-set switch off pressure of the pressure switch, pressure is limited to approx. 3.0 bar
(30 m delivery head). Consult a qualified specialist, to adapt the pressure circuit to your requirements if
necessary, see also the chapter "Adjusting the pressure switch".
4.
Scope of delivery
The scope of the delivery of this product includes:
One booster set with a connection cord, one operating manual.
Please verify that the scope of delivery is complete. Depending on the purpose of the application, additional
accessories may be necessary (please refer to the chapters titled "Installation", "Anti-dry-running protection",
"Operation of the pump with a T.I.P. prefilter" and "How to order spare parts").
If possible, keep the packing until the warranty period has expired. Please dispose of the packing materials in an
environmental-friendly manner.
5.
Installation
5.1.
General installation information
During the entire process of installation, the device must not be connected to the electrical
mains.
HWW INOX 1000 Plus
230 V ~ 50 Hz
800 Watt
IP 44
30.93 mm
(1 ")
30.93 mm
(1 ")
3,300 l/h
4.6 bar
46 m
9 m
24 l
3 mm
6 bar
5 °C
40 °C
2 °C
35 °C
40, evenly distributed
1.5 m
H05RN-F
~ 11.6 kg
2)
81 dB
)
WA
2)
77,4 dB
)
WA
69.4 dB
50 x 27 x 55 cm
31146
HWW INOX 1000 Plus TLS
230 V ~ 50 Hz
800 Watt
IP 44
, female
30.93 mm
, female
30.93 mm
3,300 l/h
4.6 bar
46 m
9 m
24 l
3 mm
6 bar
5 °C
40 °C
2 °C
35 °C
40, evenly distributed
1.5 m
H05RN-F
~ 12.0 kg
81 dB
77,4 dB
69.4 dB
50 x 27 x 55 cm
31145
2
, female
(1 ")
, female
(1 ")