AX Tech AXT-TAF205LCD Manual De Usuario página 22

4.2.3.1 Ajuste de parámetros de soldadura
AC PULSE HF TIG&LIFT TIG Parameter Adjustment
Pre-Gas,0S-1S
Up-Slope,0S-5S
Pulse Widt h,5%-100%
Pulse Frequency,0.5HZ-200HZ
AC Balance,20%-80%
St op Current , 10A-200A Input 220V
St op Current , 10A-145A Input 110V
St art Current , 10A-200A Input 220V
St art Current , 10A-145A Input 110V
Peak Current , 10A-200A Input 220V
Peak Current , 10A-145A Input 110V
Base Current , 10A-200A Input 220V
Base Current , 10A-145A Input 110V
AC Frequency,40HZ-250HZ
Down-Slope,0S-5S
Post -Gas,0.1S-10S
22
loading