TRANSMISSION GEARS LUBRICATION 
The transmission gears in the gear case need be lubricated periodically with gear
grease. Check the gear case grease level about every 50 hours of operation by
removing the sealing screw on the side of the case.
If no grease can be seen on the sides of the gear, follow the steps below to fill with
gear grease up to 3/4 capacity.
Do not completely fill the transmission gear case.
1. Position the pole saw attachment on
its chain-sprocket cover side on a
firm, flat surface, so that the sealing
screw is facing upwards (Fig. 29).
2. Use the dual-head wrench provided
to loosen and remove the injection
screw.
3. Use a grease syringe (not included)
to inject some grease into the screw
hole, taking care not to exceed 3/4 capacity.
4. Tighten the sealing screw after injection.
TRANSPORTING AND STORING
1. Do not store or transport the pole saw attachment when it is running. Always
remove the battery pack before storing or transporting.
2. Always place the guide bar sheath on the guide bar and chain before storing or
transporting the pole saw attachment. Use caution to avoid the sharp teeth of the
chain.
3. Clean the pole saw thoroughly before storing. Store the pole saw indoors, in a dry
place that is locked and/or inaccessible to children.
4. Keep away from corrosive agents such as garden chemicals and de-icing salts.
POLE SAW ATTACHMENT — PSA1000/PSA1000-FC/PSA1020/PSA1020-FC
29
Gear Case
Sealing Screw
33