Leakage Test
Gas connections on the appliance are leak tested prior to shipment. Possible
mishandling of the appliance during shipment can damage the integrity of
some parts.
A complete gas leakage test must be performed again at the installation site.
Please follow the procedure below for leakage test.
1. It is advised to make a soap / liquid detergent and water solution to identify
any holes/splits or loose fittings in the tube.
2. Make sure the control tap is in the OFF position (full disk =
) on the con-
trol panel.
3. Apply the solution to the hose using a brush or rag.
4. Turn ON the gas supply and check for bubbles from the hose. If the air
bubbles appear this indicates a leak in the hose.
5. If a leak is present, turn OFF the gas supply immediately, tighten any leak-
ing fitting carefully, turn gas again and recheck.
Appliance and Location
The appliance is for outdoor use only.
Do not use indoors or in an enclosed area.
Always maintain suitable clearance from combustible materials - minimum
800mm from the top of the unit, and a minimum of 650mm from sides.