HANDLING AND INSTALLATION
NOTE: The appliance is supplied at an oper-
ating voltage of 400V/3N (indicated on the
sticker applied to the nameplate); the con-
version to 230V/3 can be carried out as de-
scribed below.
HAZARD: Before doing any work, turn
off the general power supply.
Pull off the knob (A).
1)
B
A
C
Remove the test voltage sticker from the
6)
nameplate and apply the new one to high-
light the voltage being used.
NOTE:
After completing the operation,
check for any faults.
3378610_inst_GB
CONVERSION OF POWER SUPPLY
B
Undo the screws (B) and remove the control
2)
panel (C).
Modify the connections to the heating ele-
3)
ment terminals (D) as shown in the wiring dia-
gram at the end of the manual.
Fit the jumper (E) to make the electrical con-
4)
nection of the terminals (F).
After completing the operation, fi t everything
5)
back in place.
D
F
ENGLISH
E