NOTICE
• For safety operation and regulation compliance, it's requested to install a separate DC over-current protector or disconnect device between
battery and inverter. It may not be requested to have a disconnect device in some applications, however, it's still requested to have over-current
protection installed. Please refer to typical amperage in below table as required fuse or breaker size.
Recommended battery cable size
• For safety operation and regulation compliance, it's requested to install a separate DC over-current protector or disconnect device between
battery and inverter. It may not be requested to have a disconnect device in some applications, however, it's still requested to have over-current
protection installed. Please refer to typical amperage in below table as required fuse or breaker size.
3. Insert the battery wires flatly into battery connectors of inverter and make sure the bolts are tightened with torque of 2 Nm in clockwise
direction.
4. Make sure polarity at both the battery and the inverter/charge is correctly connected and conductors are tightly screwed into the battery
terminals
5. To firmly secure wire connection, you may fix the wires to strain relief with cable tie.
WARNING
• Installation must be performed with care due to high battery voltage in series.
• Do not place anything between the flat part of the inverter terminal andthe ring terminal. Otherwise, overheating may occur.
• Do not apply anti-oxidant substance on the terminals before terminals are connected tightly.
• Before making the final DC connection or closing DC breaker/disconnection, be sure positive (+) must be connected to positive (+) and negative
(-) must be connected to negative (-).
WORKING MODE INTRODUCTION
The inverter is a smart solar inverter that can be connected to the public electricity grid or diesel generator and manages a photovoltaic system and a
battery bank. There are three working modes:Off-grid mode, Backup mode and Economic mode, which can be set by APP or LCD display.
Off-grid Mode
Photovoltaic and battery constitute a pure off-grid system, suitable for non-grid areas.
• Solar energy provides power to the loads as first priority.
• If solar energy is not sufficient to power all connected loads, battery energy will supply power to the loads at the same time.
• Power source Priority is Solar >Bat
• Charging source Priority is Solar
Backup Mode:
The system works in this mode by default when the system is installed in an area with a grid or diesel generator. The purpose of Backup Mode is to
provide backup power during these power outages, meanwhile reduce the frequency of battery charging and discharging to extend battery life.
MANUAL DE USUARIO INVERSOR ÁLAMO
Model
Wire size
3KVA
2AWG
Wire
Beaker
2
3,63mm
80V/80A
24