ABOUT THIS MANUAL
This manual describes the assembly, installation, operation and troubleshooting of this hybrid inverter. Please read this manual carefully before
installation and operation of the equipment. Keep this manual for future reference.
This manual also provides installation and safety guidelines and unit wiring information.
SAFETY INSTRUCTIONS
The technician must carefully read this User Manual before any operation.
Do not try to repair or open this unit. Take it to a qualified service center if necessary. Improper installation of the equipment may result in electrical
hazard or fire.
Disconnect all wiring before servicing or cleaning the unit.
For optimal performance, please select the recommended wire size.
Be very careful when working with metal wristwatches or metal tools around batteries. There is a potential risk of short circuiting the battery
terminals which can lead to explosions.
Please follow the installation procedures strictly when you want to disconnect the AC or DC connectors.
This hybrid inverter must be connected to a permanent ground system.
The inverter must be installed, electrically connected, operated and maintained by a specially trained technician;
The qualified technician must be familiar with the safety regulations of the electrical system, the working process of the photovoltaic power
generation system, and the standards of the local electrical network.
INVERTER PROTECTION
WARNING
Do not disconnect the PV connectors or battery connectors when the inverter is running.
• Wait at least 10 minutes for the internal capacitors to discharge after the battery is powered off.
• Ensure that there is no voltage or current before installing or disconnecting any connectors.
• All safety instructions, warning labels, and nameplate on the inverter should not be removed or covered.
CAUTION
Do not touch any hot parts (such as the heat sink) during operation.
NOTICE
As soon as receiving the inverter please check if it is damaged during its transportation. If yes, please contact your dealer immediately.
Only qualified personnel can change the country settings.
• Adequate ventilation must be provided for inverter installation location Mount the inverter in vertical direction, and ensure that no objects block the heat
dissipation
BATTERY PROTECTION
DANGER
• Batteries deliver electric power, resulting in burns or a fire hazard when they are short circuited, or wrongly installed.
• Lethal voltages are present at the battery terminals and cables connecting to the inverter.
• Severe injuries or death may occur if the cables and terminals in the inverter are touched.
MANUAL DE USUARIO INVERSOR ÁLAMO