escription of the configuration dip switch.
The SW1 configuration dip switch is located on
the upper right part of the module .
*Factory default
D
escription of the configuration jumper.
End of line resistor.
Switch to ON if the converter is connected to the Plus system through distributors or
JP1
only in the last converter if the connection to the Plus system of the converters does
not contain distributors (input/output mode).
On
End of line resistor.
JP1
Switch to OFF in all the converters except the last one if the connection to the Plus
system of the converters does not contain distributors (input/output mode).
Off
*Factory default
Set to ON to programme the backbone (see page 26).
Once the programming has finished, return the switch to the OFF position.
Set to OFF in installations backbone encoder type (coded door panel) or
(general door panels without V2Plus inner door panel), to configure
the converter as Master, (see page 26).
Set to ON in installations backbone encoder type (general door panels
with V2Plus inner door panels), to configure the converter as Slave, (see
page 26).
Important: In a backbone or building with a backbone encoder and
access door panels, the converter must be configured as Slave.
In each backbone there must be only one door panel or converter
configured as Master, the rest must be configured as Slaves.
To reset the converter, switch to ON and then set to OFF, after a Short-
circuit or programming error.
Set to ON if there are distributors in the backbone (single or multi-user) or
the converter is connected to the riser multiplexer MC-V2Plus at a
distance of > 50m, set to OFF if the backbone installation is in daisy chain
(without distributors) or the converter is connected to the riser multiplexer
MC-V2Plus at a distance of < 50 m.