IOMM
Message/
Name
Duplicate
Module IDs
Factory Data
Not Set
Fan Speed Low
Fan Speed
Too Low
Module General
Fault
Module High
Temperature
Webasto Charging Systems, Inc.
Severity Description
Fault
At least two
modules have
duplicate CAN
IDs on
the internal
CAN bus.
Fault
The charger
factory
configuration
is missing.
Warning
The fan speed
is very low.
Fault
The fan has
stopped or
is too low
to charge.
Fault
The module
faulted with no
specific reason
reported.
Warning
The module
temperature is
very high.
ProCore Edge North America
Action(s)
Call Webasto
service.
Call Webasto
service.
Call Webasto
service.
Call Webasto
service.
Call Webasto
service.
Check for
obstructed
air flow.
Page 63 of 69 31241-03-0202