S&P MP-EMIDUAL Instrucciones De Uso página 12

Mando programador de infrarrojos con display integrado
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 1
It is possible to modify the time and day and transmit them to the product as described
at any time.
To modify only the operative temperatures follow what is indicated in paragraph 2 and
then retransmit the desired programme (P1 or P2).
Warning: In the case of a power failure lasting at least 3 consecutive hours, when the pro-
duct comes on again you will notice the operative LED flashing yellow. If you wish to con-
tinue to use the remote control it is necessary to transmit the data to the product again,
for both the current time and day and for the programme (P1 or P2). If the user does not
intervene, the LED will continue to flash and the product will operate in ECO mode (at a
temperature of 3.5° less than the temperature set on the thermostat).
Note: In the case of a power failure (> 3h) with the mode selector of the product not set
for the remote programming, when the mode selector is moved to the "PROG" position
the operative yellow LED stops flashing but time, day and program (P1-P2) information
should in any case be resent to the apparatus.
Note: the operative yellow LED flashes if time/day information are missing. Always
remember to transmit programme (P1-P2) even if previous time/day transmission stops
the flashing warning.
5. USING THE PILOT WIRE
Using the remote control excludes use of the pilot wire. When the product is purchased
it is preset for operation in "PROG" mode, using the pilot wire, according to the logics
illustrated in the instruction manual for the apparatus.
When the remote control is used for the first time the product is set to ignore any signal
applied using the pilot wire. If you wish to stop using the remote control, in order to use
the pilot wire again, it is necessary to:
Set the mode selector of the product to the "PROG" function;
Turn the apparatus off using the general switch for at least 3 hours so that the internal
autonomy runs out and the entire system is reset to the factory settings;
Turn the product on again and make sure that the operative LED is flashing yellow;
Move the product mode switch to a different position and then return to the "PROG"
mode;
Check that the operative LED has stopped flashing; the product will start to operate on
the basis of the signal applied by the pilot wire and the setting on the thermostat.
6. MISCELLANEOUS
After having programmed all the devices it is possible to put the remote control on stand-
by so as to reduce the battery consumption to a minimum and increase the autonomy.
12