Checking The Charge Level; Replacing Fuses - Dometic PLB 40 Instrucciones De Uso

Batería de litio-ferrofosfato portátil
Ocultar thumbs Ver también para PLB 40:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Using the appliance
➤ If charging the battery pack with a solar panel, observe the following require-
ments:
– Use without a solar controller:
Ensure that the solar panel outputs between 8 – 25 V DC and a maximum
charging current of 10 A.
– Use with a solar controller:
Ensure the solar charger does not need a counter voltage from the battery
side to start charging. Ensure that the maximum charging current is 10 A
(check with the solar panel manufacturer).
6.4

Checking the charge level

➤ Press the power button (fig. 2 1, page 2).
✓ The display shows the battery state of charge as a percentage.
✓ The
symbol flashes when the battery capacity is below 20 %.
6.5
Connecting consumer devices
fig. 2, page 2
➤ Open the cap for the desired device:
– USB devices (3)
– 2-pin 12 V DC socket outlet (4)
– 12 V DC socket (5)
➤ Insert your device's plug into the corresponding socket.
✓ The
symbol and the related output symbol light up.
6.6

Replacing fuses

➤ Ensure that the battery pack is not connected to AC/DC or DC/DC charger.
➤ Disconnect all loads.
➤ Press the power button for at least 3 s to switch the battery pack off.
➤ Undo the fuse holder.
➤ Replace the fuse with a 20 A 3 AG glass-slow acting fuse.