Tectro R 223 C Instrucciones De Uso página 57

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 41
H
I
empty
full
J
K
4
54
Take the manual fuel pump and insert the smooth, most rigid tube into the
3
jerrycan. Make sure that it is in a higher position than the removable tank
(Fig. H). Insert the ribbed hose into the opening of the removable tank.
Lock the valve on top of the pump (turn clockwise).
4
Squeeze the pump a few times, until fuel starts flowing into the removable
5
tank. As soon as this happens, there is no need to press any longer.
Check the removable tank fuel gauge µ while filling the tank (Fig. I). Stop
6
filling by loosening the valve on top of the pump (turn anti-clock-wise), once
the gauge indicates that the tank is full. Never overfill the tank, especially not
when the fuel is very cold (fuel expands when it heats up).
7
Let the remaining fuel in the pump flow back into the jerrycan and carefully
remove the pump. Carefully screw the fuel cap back on the tank. Clean
off any spilled fuel.
Check whether the fuel cap is straight and tightened properly. Reinstall the
8
removable tank in the heater (cap down). Close the lid.
C
IGNITING THE HEATER
A new heater may give off some smells for a short while, when it is used for the
first time. You should therefore provide extra ventilation or ignite the heater
outside the living room.
When you use the heater for the first time, first put the filled removable tank into
place, and then wait approximately 30 minutes before you ignite the heater. This
allows the glass fibre wick to soak up the fuel. Follow the same procedure when you
have completely burnt up all fuel from the tank, and after the glass fibre wick has
been replaced.
Before igniting the heater, always check the fuel indicator ² to see whether the
removable tank needs filling up.
Always ignite the heater with the ignition coil ¸. Never use matches or a cigarette
lighter.
Follow the procedure below:
Turn the knurled wick adjustment knob
1
apply more pressure you may turn it slightly further; however, it will automatically
return to the startposition.
Push in the ignition button » (Fig. K), but do not apply too much force.
2
Release the ignition button as soon as a flame is visible in the combustion
chamber ¿.
When you have ignited the heater and it shuts off again shortly after, the batteries
need to be replaced. It is best to use new alkaline batteries (4x D-size).
clockwise to its stop (Fig. J). If you
loading