3.5. ELECTRICAL CONNECTION
WARNING: Incorrect grounding of the unit may pose an electrical shock hazard. If the mains cable
is damaged, it must be replaced by a qualified electrician or an authorized service center.
All electrical work must be carried out by qualified professionals, in compliance with national and
local safety regulations.
Check that the voltage indicated on the unit corresponds to the voltage supplied by the mains.
Connect the unit separately to a mains socket with 13A capacity
Connection must be made to an adequate power socket that is easily accessible. For greater
safety, it is recommendable to install a residual current device (RCD) with a triggering current of
30 mA.
Have a qualified electrician check the device and the circuit to ensure that the power socket is
correctly connected to earth.
Note: In locations where lightning is frequent, it is recommended to use voltage surge protectors.
Do not connect the unit to the mains through an extension lead. Extension leads do not offer the
necessary safety for the appliance (e.g. danger of overheating).
The unit should not be connected to an inverter and should not be used with a multiple connection
socket adaptor, as this could damage the electronic unit.
The cable should be securely behind the appliance avoiding it getting entangled or hanging in an
unprotected manner.
WARNING: THIS APPLIANCE MUST BE GROUNDED.