08.2. Arrangement of the lighting system
The Client must make sure that there is suitable lighting for the surroundings and that the
lighting conforms to the regulations in force. In particular, the Client must arrange the positioning
of lighting that illuminates all the working area.
08.3. Arrangement of the pneumatic system
The Client must arrange a line of filtered compressed air supplied by a compressor that is suitable
for the consumption required.
Do not use compressed air that contains chemical products, synthetic oil with organic solvents,
salts or corrosive gases as they can cause damage or malfunctioning.
The line of compressed air must arrive up to the supply points of the machine. If the compressed
air contains a large amount of moisture, it may cause malfunctioning in the valves and in the
pneumatic components. Install a moisture separator downstream from the compressor to avoid
this.
08.4. Classification according to the ATEX directive
The machine conforms to the essential requisites of the EU Directive 2014/34/UE, better
known as ATEX ("Explosive atmospheres"). It is classified as group II category 3 letter G system.
The assessment procedures of conformity, carried out by an internal factory check, allow the
installation of the machine in surroundings where there may be potentially explosive atmospheres
due to the presence of gas, fumes or mist.
08.5. Equipment assembly
Air hose
Product hose
YOU MUST ALWAYS CONNECT THE EQUIPMENT AND ALL THE ELEMENTS
INVOLVED IN THE WORK PROCESS TO A GROUNDING CONNECTION TO
ELIMINATE STATIC ELECTRICITY
Air Direction
Product Direction