58
MEASUREMENT NOT
Sensor value on probe
CORRECT
device after repeated
positioning >0.01 or
<-0.01.
REFERENCE LENGTH
L_POS: Difference
DOES NOT MATCH
between length spe-
TOOL LIST
cification in the tool
memory and the input
mask.
DISTANCE FROM TOOL
Tool start position
TO BREAKAGE MONIT-
>8 mm in front of
ORING TO LARGE
breakage monitoring.
TOOL BREAKAGE
Tool broken.
LENGTH NOT PLAUS-
Cause could be due to
IBLE OR SWARF NEST
swarf or the tool has
been pulled out of the
holder.
FEED RATE FACTOR /
Measurement feed rate
MEASUREMENT RATE
in input mask too high
TOO HIGH
Maximum feed rate
factor = 3 / =>
1500 mm/min.
TOOL LENGTH NOT
L_BREAK: length read
PLAUSIBLE
out of tool memory not
plausible.
INCORRECT MODE IN
L_LENGTH: Value in in-
INPUT MASK
put mask is not 0 or 1.
BREAKAGE MONITOR-
The tool that is to be
ING ALREADY ACTIV-
monitored for breakage
ATED
already touches the
TOOL CHECK upon pro-
gram start.
BATTERY VOLTAGE
Battery flat.
TOO LOW
Check battery.
Carry out reset.
Trained specialist for
mechanical work
Clean the surface or
measurement sphere.
Tighten measurement
sphere.
Carry out reset.
Trained specialist for
mechanical work
Correct the tool length
in the input mask.
Carry out reset.
Trained specialist for
mechanical work
Correct the start posi-
tion of Z-.
Carry out reset.
Trained specialist for
mechanical work
Replace tool.
Remove swarf.
Trained specialist for
mechanical work
Check whether the tool
has been pulled out of
the holder.
Carry out reset.
Trained specialist for
mechanical work
Reduce measurement
feed rate.
Carry out reset.
Trained specialist for
mechanical work
Check tool length in
controller.
Check difference
between tool tip and
tool setting dimension
D1 in input mask yy. D1
length is checked.
Check correctness of
position determination
of the XC with L_POS.
Carry out reset.
Trained specialist for
mechanical work
Change mode in input
mask:
0 = only measure tool
length.
1 = overwrite tool
length.
Carry out reset.
Trained specialist for
mechanical work
Correct the start posi-
tion of Z+.
Carry out reset.
Trained specialist for
mechanical work
Change the battery.