9.1 Oil change.
1 Keep the engine running during 5 to 10 minutes for the oil to reach some
temperature and reduce its viscosity (more liquid). This way it will be easier to
extract it completely.
2 Open the maintenance access cover by releasing the closing screw.
3 Open the evacuation covers so the oil may pour through this hole out of the
equipment and place a tray under the equipment to collect the oil.
4 Unscrew the oil draining screw by turning counter clockwise and allow all the
spent oil to pour out.
5 Once all of the oil has been extracted, place the evacuation cover again, as
well as the drain plug. Clean any oil spills.
6 Open the oil plug and refill with the recommended oil (see 4.2 point of this
manual).
8 After changing the oil, wash your hands with soap.
IMPORTANT: In order to comply with environmental requirements, the used oil
must be placed in a sealed container and taken to the service station for
recycling. Do not discard the trash and do not spill on the floor.