11. Tap up icon to enter to dH,
Tap the on/off icon, when it
displays digits, tap up icon to
increase the value or tap down icon
to decrease the value.
After parameter setting, tap on/off
icon back to dH
13. Tap up icon to enter to 5E,
adjust the water inlet flow to
about 7L/min;start to calibrate the
load of the whole machine, and
display P after the calibration is
successful ( only for G30)
5.Exit forced mode
Continuously tapping the up icon when it display qU, tap on/off icon to exit the forced mode
and finish secondary gas pressure setting. Then, re-ignite the machine as normal using
situation.
15. Tap up icon to qU
12. Tap up icon to enter to Fd,
Tap the on/off icon, when it
displays digits, tap up icon to
increase the value or tap down icon
to decrease the value.
After parameter setting, tap on/off
icon back to Fd
14. Tap up icon to enter to 5P,
start to calibrate the air pressure
of the whole machine, and display
P after the calibration is successful
16. Tap on/off icon to exit
forced mode and the
setting finished