Johnson ARGON Serie Manual De Instrucciones página 46

Idiomas disponibles

Idiomas disponibles

● Installation of gas pipe
a. Caution
Be sure to select a special gas rubber hose or a suitable rigid tube and a gas relief valve.
· Select the pipe size according to Table 1.
· The length of the rubber hose shall not exceed 2 meters.
· The rubber hose must be connected to the red line position of the gas inlet joint and secured
with a clamp.
· After installation, check the unit with suds for gas leak.
b. Connect the unit to the gas joint with G1/2 pipe thread.
When LPG is used, connect the attached gas inlet hose joint to the gas supply pipe joint of the
unit (be sure to mount a rubber sealing ring), then connect it with an Ф 9.5mm special gas rubber
hose. Insert one end into the hose joint of the unit's gas inlet until the hose is fitted over the red
groove of the joint, and hold it with a clip.
Installation of water inlet and outlet pipes.
Connect the water inlet and outlet pipes and tap water pipe of the unit with an Ф10mm metal hose,
or with a water pipe with an inner diameter of greater than 15mm.
Add a rubber sealing gasket when a metal hose is used.
Water outlet joint
Gasket
Nut
Water outlet
Gas inlet pipe
pipe
Gas pipe joint
Rubber sealing ring
Hose pipe joint
Work carrier
Gas rubber hose
Gas pipe joint
Water inlet pipe joint
Water inlet pipe
NOTE
15
V.3
loading

Este manual también es adecuado para:

Argon11butArgon11gn