SET MENU - TEMPERATURES T1, T2, T3 SETTING
Access the SET menu to change the values of the 3 temperatures used in automatic
operation. The factory setting includes:
• T1 = 5°C, T2 = 15°C, T3 = 18°C (heating/winter operation )
• T1 = off, T2 = 23°C, T3 = 25°C (conditioning/summer operation
How to change the temperature values T1/ T2/ T3
Initial screen
Change T1
To exit the temperature change:
• press the key
once to return to the configuration menu
• press the key
twice to exit the menu and return to the initial screen
Note: temperature values between L0 (minimum value)
and kI (maximum value) are allowed.
These factory values are: L0 = 2°C, kI = 50°C but can be modified through the ADV
menu.
Note: the condition T1 ≤ T2 ≤ T3 must be respected.